Published September Origi- nally approved in Last previous edition approved in as 3. E – 89a (). Annual Book of ASTM Standards. Buy ASTM E TEST METHODS FOR CHEMICAL ANALYSIS OF COPPER ALLOYS from SAI Global. These test methods for the chemical analysis of metals and alloys are primarily intended as referee methods to test such materials for.

Author: Akinorr Vutaur
Country: Lebanon
Language: English (Spanish)
Genre: Science
Published (Last): 11 February 2009
Pages: 107
PDF File Size: 7.3 Mb
ePub File Size: 11.73 Mb
ISBN: 806-5-88971-608-3
Downloads: 61861
Price: Free* [*Free Regsitration Required]
Uploader: Gardadal

Aspirate the reference solution, the test solution, and calibration solutions, in the order of increasing readings. Evaporate the solution to near dryness, cool, and dissolve the residue in a few millilitres of water. Please 4e78 to your authorized staff account to use this feature. Determine the appropriate concentration range as directed in The absorption by the e47 solution of the silver resonance line energy at The anode cylinder should be approximately 12 mm in diameter and 50 mm in height and the over-all height of the anode should be approximately mm.

No other units of measurement are included in this standard.

ASTM E478 – 08(2017)

There were no books found for the applied search filters. Wash the cover and walls of the beaker, dilute to mL, and heat to dissolve salts. Are you sure you want to empty the cart? Discard the organic layer. Preparation of Calibration Curve While maintaining this adjustment, take photometric readings of the calibration solutions Note Avoid adding excessive amounts of formaldehyde.

  CISCO EA2700 PDF

Calculate the percentage of iron as follows: Add 10 mL of HCl and dilute to 1 L. A spiral anode of this description will have a surface area of 9 cm 2. Photometric measurement is made at approximately nm. The solution is stable for several months when stored in plastic or borosilicate glass bottles.

Summary of Test Method Gauze cathodes are recommended, and shall be made preferably from mesh gauze woven from wire approximately 0.

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. Quickly remove the cathode, rinse it in water, and then dip into two successive baths of ethanol or methanol. Add HF as needed to decompose high-silicon alloys.

Your consent to our cookies if you continue to use this website. The data are summarized in Table Repeat at least twice with no change in parameters. The copper oxalyldihydrazide complex is formed with the copper remaining in the electrolyte. Cool, dilute to volume, and mix. Treat an aliquot the same size as that of the test solution as directed in Insert a roll of sheet nickel. Repeat this extraction until no further precipitation occurs.

  INTEREST RATE OPTION MODELS REBONATO PDF

The addition of 1 g of benzoic acid per litre will prevent bacterial growth. Remember me for one month. AAB 1 2 We share information about your activities on the site with our partners and Google partners: Add 5 mL more of diethyldithiocarbamate solution to the separatory funnel and mix.

Norma ASTM E()

Prepare fresh prior to use. Photometric Determination of the Residual Copper in the Electrolyte E has been adtm by Practice E E Standard Terminology Relating to Metallography. Dilute to 1 L with water. Precipitate the iron and tin as before and heat to boiling to coagulate the precipitate. Boil the solution gently for 45 min.

Cool, add 5 g of potassium iodide KIand stir until the KI is dissolved. It is assumed that all who use these methods will be trained analysts capable of performing common laboratory procedures skillfully and safely. The more rapid procedure requires the use of gauze electrodes.

If the entire electrolyte is to be used, proceed directly with the neutralization. Add 50 mL of hot water and, if the solution is clear, proceed as described in A cathode of these dimensions will have a surface area of cm 2 exclusive of the stem.